The CCI Model CSS12 shall be constructed of circular stainless steel bands, which bolt together forming a shell around the carrier pipe. The casing spacer shall be lined with a ribbed PVC extrusion with a retaining section that overlaps the edges of the shell and prevents slippage. The casing spacer shall be designed with risers and runners to support the carrier pipe within the casing and maintain a minimum clearance of 1.0 in. between the casing ID and the carrier pipe OD.
The runners shall be Glass Reinforced Polymer with ends of the runners beveled to facilitate installation over rough weld beads or the welded ends of misaligned or deformed casing pipe. The runners shall be attached to support structures (shell or risers) at appropriate positions to properly support the carrier pipe within the casing and for ease of installation. They shall have a minimum length of 11.0 in. and a minimum width of 2.0 in.
The shell shall be manufactured of 12.0 in. wide, 14-gauge stainless steel. The riser shall be constructed of 10-gauge stainless steel, 10.75 in. minimum lengths with a height to be determined based on the annular space between the carrier pipe OD and the casing ID.